Semenov, A. O.Popov, S. V.Yakhin, S. V.Yeleussinov, B.Sakhno, T. V.Семенов, Анатолій ОлексійовичПопов, Станіслав ВячеславовичЯхін, Сергій ВалерійовичСахно, Тамара Вікторівна2024-02-192024-02-192024Semenov A., Popov S., Yakhin S., Yeleussinov B., Sakhno T. Assessment of the danger of using ultraviolet lamps in electrical systems. Przegląd Elektrotechniczny. 2024. № 2. P. 152–155. DOI: https://doi.org/10.15199/48.2024.02.310033-2097https://dspace.pdau.edu.ua/handle/123456789/16820To determine the photobiological safety of UV lamps, the following measurements were carried out: spectral irradiance, total actinic irradiance in the wavelength range of 200-400 nm, and irradiance in the UVA range (320-400 nm). These parameters were measured using the optical radiation system OST-300. The photobiological safety of LUF 40-1, LE 15 lamps and their radiation risk group are established in accordance with EN 62471. The levels of UV radiation generated by LE 15 low pressure discharge lamps at a distance of 0.25 m belong to the high risk group (GR3), and LUF 40-1 - in the group of insignificant risk (GR1). Calculations and recommendations on safe radiation doses when using lamps in electrotechnical systems of photobiological influence are given.enPhotobiological safetyUV irradiancecarcinogenic safety of radiationspectral intensityAssessment of the danger of using ultraviolet lamps in electrical systemsArticle